Carrier 48fc 15 ton.

Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES AND BENEFITS. Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

This product has been superseded by. 48FCEA04A3A5-0A0A0 - 3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTUFull-scale Carrier quality for a variety of equipment types. DXF/CAD templates are full scale 2D drawings of Carrier products. Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. ... 3-28 Ton Rooftop Units – 48/50TC(Q), 48/50KC(Q), 48/50HC(Q), 48/50LC, EnergyX® models. 48 ...American Airlines is ending the AirPass program, which offered fixed rates for travel and a ton of lucrative perks. While most travelers purchase airline tickets directly from the ...There are 2,000 pounds in one ton. Tons and pounds are both units of measurement that describe mass. The abbreviation for ton is “T,” while the abbreviation for pound is “lb” or “l...24 2 800 / 600 23000 12.0 15.0 30 2-1/2 1000 / 750 29000 12.0 15.0 36 3 1200 / 900 35400 12.5 16.0 42 3-1/2 1400 / 1050 42000 12.5 16.0 48 4 1600 / 1200 47500 12.3 16.0 60 5 1750 / 1200 57000 12.3 16.0 LEGEND dB ---Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of Performance

Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting (144 pages) Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant. Table of Contents General. Manual is suitable for 4 more products: 48GC Series 48GC 05 48GC 04 48GC 06. Brand: Carrier | Category: Air Conditioner | Size: 4.05 MB.

d1049ui2fjityy.cloudfront.net

6 to 23 Nominal Tons. 48LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have some of the industry’s highest IEER’s available. The multi stage cooling compressor logic allows for added comfort, energy savings and humidity control.Carrier 48fc 15 Ton, Carrier Commercial Packaged Outdoor Commercial Products Portland, OR, Commercial Cooling Showcase 2019 2019-05-06 ACHR News. Home; 2024-03-04; 2024-03-03; 2024-03-02; ... Carrier 48FC Single Package Rooftop Gas Heat-Electric Cooling Units Instruction Manual.Up to 15.6 SEER, 13.0 IEER, and 12.2 EER. Gas efficiencies up to 82%. Standard cooling operating range up to 125 °F (52°C) and down to 35°F (2°C). Low ambient controllers can bring cooling operation down to -20°F (-29°C) Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center ...GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and …

Spore.warden

5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48FCEA06A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models 06 = 5 Tons A = No Smoke or CO 2 sensor 3 = Direct Drive, ... Brand Carrier; Availability Available for Delivery; Warehouse …

10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; Availability Available ... IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Carrier WeatherMaker rooftop unitCarrier Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB. Carrier 48FC Series Pdf User Manuals. View online or download Carrier 48FC Series Installation Instructions. 10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …

48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Medium Heat. ... Carrier 6 Ton, 11.0 EER Package RTU Medium Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,460/3 ... IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using …Sizes 04-06 models use single-stage cool-ing capacity control. FEATURES. Standard Base Unit Cabinet. Puron (R-410A) HFC refrigerant • Access panels with easy grip handles. SEER of 14.0 • Innovative, easy starting, no-strip screw feature on unit. Meets or exceeds ASHRAE 90.1 energy efficiency levels access panels.Carrier24SCA4. Up to 16 SEER2 for moderate energy savings with standard comfort features. 4.4 out of 5 stars. 18 Reviews. 5 Star. 67%. 4 Star. 22%. 3 Star.els are in addition to the 3 to 5 ton models with SEERs up to 17.5 and 12.5 to 23 ton models with IEERs up to 19.1 to provide a full range offering. Ultra high efficiency With IEERs up to 20.8, these new WeatherExpert models help to contrib-ute in LEED credits and help qualify for rebates. The high IEER efficiencies areSEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain48FCEA06A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models 06 = 5 Tons A = No Smoke or CO 2 sensor 2 = Direct Drive, Eco Blue, Medium Static Option A = Al/Cu - Al/Cu 5 = 208/230-3-60 0 = Electro-mechanical Controls can be used with W7212 A = No Air Intake or Exhaust 0 = No Convenience Options A = No ...

All WeatherMaker 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unex-pected jobsite complications. Comfort control Carrier’s Round Tube Plate Fin coil design helps maximize heat transfer and reliable operation. 1. Third-party trademarks and logos are property of their respective owners.

Most of Carrier’s 3−12.5 ton 48HC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls. ... SEER up to 15.6, EER up to 13.0 IEER’s up to 14.0 with single speed indoor fan motor, and up to 16.0 with SAV (Staged Air Volume) 2−speed/VFDCarrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; Carrier Enterprise Mid-Atlantic Technical Support Site CE - Carrier EnterpriseUp to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP. Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt ...Description. 48FCFM16A3A6-0A0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Model. 16 = 15 Tons. A = No Smoke or CO 2 …Three carrier hvac units named finalists in consulting-specifying Carrier 48tced manuals Weathermaker® 48fc single-packaged rooftop units with ecoblue™ technology Manualslib manuals 48tc. Manual and Guide Full List. Home; ... Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check Details.Do you want to replace your air conditioner this summer? Click here to check out the detailed Lennox vs. Carrier comparison to make a better decision. Expert Advice On Improving Yo... Carrier

In case you didn't know chords and lyrics

Carrier 48GC Series Pdf User Manuals. View online or download Carrier 48GC Series Installation Instructions ... Gas Heat (48FC and 48GC) 8. Controls Quick Set- -Up. 8. Control Set Point and Confirmation Log. 8. Initial Startup. 8. ... Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector ...

This product has been superseded by. 48FCEA04A3A5-0A0A0 - 3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU48FC-4-7-02SB. 48FC 04-07 WEATHERMAKER® SERIES WITH ECOBLUETM TECHNOLOGY SINGLE PACKAGE ROOFTOP GAS HEAT/ELECTRIC COOLING …3 UNIT ARRANGEMENT AND ACCESS General Figures 1 and 2 show the general unit arrangement and access locations. Fig. 1 — Access Panels and Components, Front Fig. 2 — Typical Access Panel Locations, Rear Routine Maintenance04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert onlyGas Heating/Electric Cooling Models (48FC) 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3.Two-stage cooling capacity control (sizes 08 to 24) Up to 13.4 SEER, 12.2 IEER, 11.2 EER, HSPF 7.7, and COP 3.4. Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit. Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.Replacement for. 48KCEA06A2A5-0A0A0 - 5.0T G/E RTU PURON 208/230-3 MED FAN; 48TJE006---5--GA - 5.0T G/E RTU 3PH STD HEAT W/ALT MTR; 48FCEA06A2A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert onlyAir Conditioner Carrier 48FC Installation Instructions Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) Air Conditioner Carrier 48LJ Installation, Start-Up And Service Instructions ManualFig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas HeatCarrier contractors are ready to help you create your ideal home environment. Find an Expertkeyboard_arrow_right. Explore HVAC Systems & Products. Learn about our innovative products and how they can help improve your comfort. Browse Productskeyboard_arrow_right. Learn Heating & Cooling Basics.

Fig. 1 — 48FC 04-07 Model Number Nomenclature MODEL NUMBER RATED INDOOR AIRFLOW (CFM) 48FC*A/B04 1050 48FC*A/B05 1500 48FC*A/B06 2000 48FC*M/N07 2400 Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 ... Replacement for. 48TCED08A2A6-0A0G0 - Gas Heat/Electric Cool Rooftop, 2-Stg 7.5T 460-3-60 Medium Fan; 48TCEM08A2A6-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert onlyInstagram:https://instagram. dmv inspection station cherry hill nj The price for a ton of coal varies greatly depending on what kind of coal it is. According to the U.S. Energy Information Administration, the average price for coal in 2012 was $39... the russian lathe incident full video The 1937-1938 Mack Jr half-ton pickup was the big-rig maker's downsize experiment. See pictures and learn about the 1937-1938 Mack Jr half-ton pickup. Advertisement Mack hoped that... Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: Single cooling stage models are available from 3 -- 10 ton. Two cooling stage models are available from 7.5 -- 15 ton. SEER up to 13.0. (up to 13.4 with ECM motor) EER's up to 11.1. (up to 11.4 with ECM motor) apt2b tuxedo two piece sleeper sectional Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat Carrier Puerto Rico - Air Conditioning payson weather 10 day CE - Carrier Enterprise Replacement for. 48TCED08A2A6-0A0G0 - Gas Heat/Electric Cool Rooftop, 2-Stg 7.5T 460-3-60 Medium Fan; 48TCEM08A2A6-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU kenton county jailtracker ky 14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only michigan pitbull breeders Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB. Carrier 48FC Series Pdf User Manuals. View online or download Carrier 48FC Series Installation Instructions. recent arrests in winston county alabama Carrier 48FC Installation Instructions (2 pages) Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory Manual is suitable for 4 more products: 48 GC 48 HC 48 LC 48 TC12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM14A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... jeep wrangler jk lug nut size 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A2A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... flea market webster fl A Pg 1 11-22 Replaces: 48FC-8-14-01SB. 48FC 08-16 size units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society ... blockhead beerworks menu Carrier 48FC Single Package Rooftop Gas Heat-Electric Cooling Units Instruction Manual. Carrier 48FCFM16A3A6-0A0A0 15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU DCNE. Carrier Commercial Packaged Outdoor Units Melrose Park, IL. mary vanderbilt S Two cooling stage models are available from 7.5 -- 15 ton. S SEER up to 13.0. S EER’s up to 11.1. S IEER’s up to 11.8. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time andCarrier 48FC Installation Instructions (2 pages) Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory Manual is suitable for 4 more products: 48 GC 48 HC 48 LC 48 TC